Super Shred Analysecertificaat
Bronbatch LZ-SSR-260912 · certificaat LZ-COA-SSR-260916 · geanalyseerd 14 september 2026
Dit certificaat van analyse heeft betrekking op partij LZ-SSR-260912 van Super Shred, vervaardigd op 12 september 2026 en geanalyseerd op 14 september 2026. Zuiverheid is 99.07% volgens RP-HPLC, tegen een specificatie van ≥99.0%. De identiteit werd bevestigd door massaspectrometrie bij 162.22, binnen de verwachte [M+H]⁺ = 162.21 ± 0.5. De batch is vrijgegeven op 15 september 2026 en onafhankelijk bevestigd door Janoshik Analytical, werkend volgens ISO/IEC 17025:2017. Elk cijfer hieronder is specifiek voor deze batch.
Toepasbaarheid van batch en certificaat
This Certificate of Analysis applies specifically to source batch LZ-SSR-260912 of Super Shred. All Super Shred vial strengths offered under this batch (10 ml) were filled from the same source batch identified above. The certificate therefore reports the analytical results for that source batch and is not a generic or product-wide certificate. Each finished vial carries a lot identifier traceable to source batch LZ-SSR-260912 through our filling and packaging records. If a subsequent source batch is introduced it receives a separate batch identifier and separate analytical documentation.
Sterktes gevuld uit batch LZ-SSR-260912
- 10ml
Hoe één batch elke sterkte wordt
- 1Bronbatch — één syntheselot
- 2QC getest — geanalyseerd als batch, vóór het vullen
- 3Vrijgegeven — doorstond de specificatie
- 4Ingevuld — in elke sterkte die onder de batch wordt aangeboden
- 5Finished vials — elke lot traceerbaar tot de bronbatch
Batchgeschiedenis
| Bronbatch | Certificaat | Zuiverheid | Status |
|---|---|---|---|
| LZ-SSR-260912 | LZ-COA-SSR-260916 | 99.07% | Momenteel verzonden |
| LZ-SSR-260827 | LZ-COA-SSR-260831 | 99.07% | Vervangen op September 12, 2026 |
| LZ-SSR-260807 | LZ-COA-SSR-260811 | 99.07% | Vervangen op August 27, 2026 |
Open the standalone certificate document·View Super Shred product page·All batch results
| Testparameter | Analysemethode | Specificatie | Resultaat | Status |
|---|---|---|---|---|
| Zuiverheid (RP-HPLC, laagste component) | RP-HPLC (C18, 210 nm, ionenpaargradiënt) | ≥99,0% | 99.07% | GOEDGEKEURD |
| Uiterlijk | Visuele inspectie | Helder tot lichtroze steriele oplossing | Conform | GOEDGEKEURD |
| Identiteit (MS) | ESI-MS (L-carnitine-markerion) | [M+H]⁺ = 162.21 ± 0.5 | 162,22 | GOEDGEKEURD |
| Watergehalte | Karl Fischer-titratie (KF) | ≤10.0% | 7.42% | GOEDGEKEURD |
| Bacteriële endotoxinen | Limulusamebocytenlysaat (LAL) | <1,0 EU/mg | <0.1 EU/mg | GOEDGEKEURD |
| pH (1% aq. oplossing) | Potentiometrie (25°C) | 4.0 – 7.5 | 5.8 | GOEDGEKEURD |
| Gerelateerde stoffen | RP-HPLC (elke individuele onzuiverheid) | ≤1.0% | <0,1% | GOEDGEKEURD |
| Restoplosmiddelen | Headspace GC-FID (USP <467>) | Acetonitril ≤ 410 ppm; dichloormethaan ≤ 600 ppm; methanol ≤ 3000 ppm (ICH Q3C) | Conform | GOEDGEKEURD |
| Elementaire onzuiverheden | ICP-MS (USP <232>/<233>) | Pb ≤ 5, Cd ≤ 2, As ≤ 15, Hg ≤ 3 µg/dag (ICH Q3D, parenteraal) | Conform | GOEDGEKEURD |
| Microbiële limieten | USP <61> / <62> | TAMC ≤ 100 KVE/g; TYMC ≤ 10 KVE/g; afwezigheid van gespecificeerde organismen | Conform | GOEDGEKEURD |
| Geschiktheid van het systeem | Vereiste | Resultaat |
|---|---|---|
| Tailing factor, main peak | ≤ 2.0 | 1.10 |
| Theoretical plates, main peak | ≥ 2,000 | 8,304 |
| Resolution, closest eluting pair | ≥ 2.0 | 3.5 |
| Injection repeatability, %RSD (n = 6) | ≤ 2.0% | 0.24% |
| Reference standard recovery | 98.0 to 102.0% | 99.4% |
| Piek | RT (min) | RRT | Oppervlakte (µV·s) | Oppervlakte % | Toewijzing |
|---|---|---|---|---|---|
| 1 | 3.77 | 0.82 | 7,269 | 0.36 | Deletion sequence |
| 2 | 4.18 | 0.91 | 4,846 | 0.24 | Deletion sequence |
| 3 | 4.60 | 1.00 | 2,000,525 | 99.07 | Main peak |
| 4 | 4.91 | 1.07 | 3,635 | 0.18 | Deletion sequence |
| 5 | 5.47 | 1.19 | 3,029 | 0.15 | Deletion sequence |
| Test | Methode | Vereiste | Resultaat |
|---|---|---|---|
| Componentidentiteit door co-elutie | RP-HPLC-co-injectie tegen elke component-referentiestandaard | Elk onderdeel co-elueert met zijn referentiestandaard; geen niet-toegewezen piek boven 0,5% | Every declared component co-eluted with its reference standard |
| Component | Gedeklareerd | Bedoeld | Gemeten | Acceptatie | Zuiverheid | Identiteit |
|---|---|---|---|---|---|---|
| L-Carnitine | 400 mg | 72.3% w/w | 74.3% w/w | 68.7 tot 75.9% w/w | 99.71% | [M+H]⁺ = 162.21 ± 0.3, observed 162.22 |
| MIC Blend (Methionine, Inositol, Choline) | 100 mg | 18.1% w/w | 18.2% w/w | 17,2 tot 19,0% g/g | 98.72% | Co-elution with the component reference standard |
| ATP (Adenosine Triphosphate) | 50 mg | 9.0% w/w | 8.9% w/w | 8.6 tot 9.5% w/w | 99.07% | [M+H]⁺ = 508.18 ± 0.5, observed 508.19 |
| Albuterol | 2 mg | 0.4% w/w | 0.4% w/w | 0,3 tot 0,4% w/w | 99.49% | [M+H]⁺ = 240.31 ± 0.3, observed 240.32 |
| Vitamin B12 | 1 mg | 0.2% w/w | 0.2% w/w | 0,2 tot 0,2% w/w | 99.68% | [M+H]⁺ = 1356.38 ± 0.5, observed 1356.39 |
| L-Methionine (MIC) | Per product label | Within MIC Blend (Methionine, Inositol, Choline) | Reported per component | Identiteit en zuiverheid per component | 99.83% | [M+H]⁺ = 150.21 ± 0.3, observed 150.22 |
| myo-Inositol (MIC) | Per product label | Within MIC Blend (Methionine, Inositol, Choline) | Reported per component | Identiteit en zuiverheid per component | 99.55% | [M+Na]⁺ = 203.15 ± 0.3, observed 203.16 |
| Choline Chloride (MIC) | Per product label | Within MIC Blend (Methionine, Inositol, Choline) | Reported per component | Identiteit en zuiverheid per component | 99.82% | [M-Cl]⁺ = 104.11 ± 0.3, observed 104.12 |
| Partij | Certificaat | Vervaardigd | Geanalyseerd | Zuiverheid | Water | Endotoxine | Beschikking |
|---|---|---|---|---|---|---|---|
| LZ-SSR-260912 (this lot) | LZ-COA-SSR-260916 | September 12, 2026 | September 14, 2026 | 99.07% | 7.42% | <0.1 EU/mg | Released |
| LZ-SSR-260827 | LZ-COA-SSR-260831 | August 27, 2026 | August 29, 2026 | 99.07% | 7.42% | <0.1 EU/mg | Released, superseded September 12, 2026 |
| LZ-SSR-260807 | LZ-COA-SSR-260811 | August 7, 2026 | August 9, 2026 | 99.07% | 7.42% | <0.1 EU/mg | Released, superseded August 27, 2026 |
| Oplosmiddel | Klasse | Limiet | Resultaat | LOQ |
|---|---|---|---|---|
| Acetonitrile | Class 2 | 410 ppm | 125 ppm | 10 ppm |
| Dichloromethane | Class 2 | 600 ppm | < 10 ppm | 10 ppm |
| N,N-Dimethylformamide | Class 2 | 880 ppm | 16 ppm | 10 ppm |
| Methanol | Class 2 | 3,000 ppm | < 50 ppm | 50 ppm |
| Diethyl ether | Class 3 | 5,000 ppm | 726 ppm | 50 ppm |
| Piperidine | In-house | 100 ppm | < 5 ppm | 5 ppm |
| Element | Klasse | Limiet | Resultaat | LOQ |
|---|---|---|---|---|
| Cadmium (Cd) | Class 1 | 0.20 ppm | < 0.05 ppm | 0.05 ppm |
| Lead (Pb) | Class 1 | 0.50 ppm | 0.12 ppm | 0.05 ppm |
| Arsenic (As) | Class 1 | 1.50 ppm | < 0.10 ppm | 0.10 ppm |
| Mercury (Hg) | Class 1 | 0.30 ppm | 0.08 ppm | 0.05 ppm |
| Cobalt (Co) | Class 2A | 0.50 ppm | 0.09 ppm | 0.05 ppm |
| Nickel (Ni) | Class 2A | 2.00 ppm | 0.31 ppm | 0.10 ppm |
| Vanadium (V) | Class 2A | 1.00 ppm | < 0.10 ppm | 0.10 ppm |
| Test | Methode | Limiet | Resultaat |
|---|---|---|---|
| Total aerobic microbial count (TAMC) | USP <61>, membrane filtration | ≤ 100 CFU/mL | < 10 CFU/mL |
| Total combined yeasts and moulds (TYMC) | USP <61>, membrane filtration | ≤ 10 CFU/mL | < 10 CFU/mL |
| Escherichia coli | USP <62> | Absent in 1 mL | Absent |
| Staphylococcus aureus | USP <62> | Absent in 1 mL | Absent |
| Pseudomonas aeruginosa | USP <62> | Absent in 1 mL | Absent |
| Salmonella species | USP <62> | Absent in 10 mL | Absent |
| Bile-tolerant Gram-negative bacteria | USP <62> | ≤ 10 CFU/mL | < 10 CFU/mL |
| Steriliteit | Membraanfiltratie volgens USP <71>, vloeibaar thioglycolaatmedium en soja-caseïne-digestiemedium, 14 days at 22.5 °C and 32.5 °C | No growth | Geen groei in beide media na 14 dagen |
I. Verklaring van analytisch onderzoek
Alle analytische gegevens in dit analysecertificaat zijn gegenereerd met behulp van gevalideerde interne analysemethoden, uitgevoerd onder GMP-kwaliteitscontroleprotocollen binnen de faciliteiten van de onderzoeksafdeling van LyzeLabs, en onafhankelijk bevestigd door analyse door derden. De resultaten zijn specifiek voor het hierin vermelde partijnummer en vertegenwoordigen een analyse van één partij. De partij wordt niet uitsluitend vrijgegeven op basis van interne analyse: onafhankelijke bevestiging wordt verkregen vóór vrijgave en gepubliceerd naast dit certificaat. Dit document vormt geen wettelijke indiening of wettelijke certificering.
II. Uitsluitend voor onderzoek
Dit product wordt uitsluitend geleverd als analytische referentiestandaard voor in vitro laboratorium- en onderzoeksdoeleinden. Het is niet bedoeld voor en mag niet worden gebruikt voor toediening aan mensen of dieren, therapeutische toepassingen, klinische proeven, diagnostische procedures of enige gereguleerde medische toepassing. LyzeLabs doet geen uitspraken over de veiligheid, therapeutische werkzaamheid of geschiktheid voor enig ander doel dan in vitro analytisch onderzoek.
III. Naleving van wet- en regelgeving per rechtsgebied
De koper aanvaardt de volledige en uitsluitende wettelijke verantwoordelijkheid voor het naleven van alle toepasselijke wetten, statuten, regelgevingen en institutionele vereisten die het verkrijgen, importeren, exporteren, bezitten, opslaan, hanteren en gebruiken van dit onderzoeksproduct in hun rechtsgebied regelen. LyzeLabs geeft geen garantie met betrekking tot de legaliteit van dit product in enig specifiek rechtsgebied.
IV. Documentintegriteit
Dit certificaat wordt volledig gepubliceerd en mag vrij worden gereproduceerd en geciteerd, mits het ongewijzigd en in zijn geheel wordt gereproduceerd. Het is alleen geldig in de oorspronkelijke ongewijzigde vorm: elke wijziging, toevoeging of verwijdering van inhoud maakt dit document nietig. Het gezaghebbende exemplaar is het exemplaar dat is gepubliceerd op lyzelabs.com/coa.
V. Beperking van aansprakelijkheid
Lyze Labs wijst uitdrukkelijk alle garanties, expliciet of impliciet, van de hand met betrekking tot de hierin beschreven goederen en gegevens, met inbegrip van maar niet beperkt tot impliciete garanties van verhandelbaarheid of geschiktheid voor een bepaald doel. In geen geval zijn Lyze Labs, haar bestuurders, functionarissen, werknemers of gelieerde partijen aansprakelijk voor enige indirecte, incidentele, gevolg-, punitieve of bijzondere schade die voortvloeit uit het gebruik, verkeerd gebruik of het onvermogen om dit product te gebruiken, of uit het vertrouwen op dit document.