WARNING: We only accept orders through this website. No TikTok, Telegram, Instagram, or marketplace.

Lipo-C (Carnitine + B-Complex Lipotropic) Certificate of Analysis

Source batch LZ-LIPC-260826 · certificate LZ-COA-LIPC-260830 · analysed August 27, 2026

This Certificate of Analysis covers batch LZ-LIPC-260826 of Lipo-C (Carnitine + B-Complex Lipotropic), manufactured on August 26, 2026 and analysed on August 27, 2026. This is a co-formulation of 5 components: L-Carnitine, Cyanocobalamin, L-Methionine, Inositol, Choline Cl. Each is assayed against its own reference standard, and the headline figure of 99.24% is the LOWEST single-component purity, not a figure for the mixture. The batch was released on August 29, 2026 and independently confirmed by Janoshik Analytical, working to ISO/IEC 17025:2017. Every figure below is specific to this batch.

Batch and certificate applicability

This Certificate of Analysis applies specifically to source batch LZ-LIPC-260826 of Lipo-C (Carnitine + B-Complex Lipotropic). All Lipo-C (Carnitine + B-Complex Lipotropic) vial strengths offered under this batch (10 ml) were filled from the same source batch identified above. The certificate therefore reports the analytical results for that source batch and is not a generic or product-wide certificate. Each finished vial carries a lot identifier traceable to source batch LZ-LIPC-260826 through our filling and packaging records. If a subsequent source batch is introduced it receives a separate batch identifier and separate analytical documentation.

Strengths filled from batch LZ-LIPC-260826

  • 10ml

How one batch becomes every strength

  1. 1Source batchone synthesis lot
  2. 2QC testedanalysed as a batch, before any filling
  3. 3Releasedpassed specification
  4. 4Filledinto every strength offered under the batch
  5. 5Finished vialseach lot traceable to the source batch

Batch history

Source batches of Lipo-C (Carnitine + B-Complex Lipotropic), current batch first
Source batchCertificatePurityStatus
LZ-LIPC-260826LZ-COA-LIPC-26083099.24%Currently shipping
LZ-LIPC-260806LZ-COA-LIPC-26081099.24%Superseded August 26, 2026

Open the standalone certificate document·View Lipo-C (Carnitine + B-Complex Lipotropic) product page·All batch results

LYZE LABS™
Research Division · Quality Control
CERTIFICATE OF ANALYSIS
Analytical Reference Standard
Certificate No.LZ-COA-LIPC-260830
Lot / Batch No.LZ-LIPC-260826
Manufacturing DateAugust 26, 2026
Analysis DateAugust 27, 2026
Issue DateAugust 29, 2026
Expiry DateAugust 2028
Document StatusRELEASED
Product Information
Product NameLipo-C (Carnitine + B-Complex Lipotropic)
Catalog CodeLZ-LIPC-30ML
CAS Number541-15-1 / 68-19-9 / 63-68-3 / 87-89-8 / 67-48-1
Molecular WeightBlend (5 components)
HPLC Purity99.24%
AppearanceClear to slightly red sterile solution
Analysis ScopeBatch-Level Analysis (All Variants)
Description: Lipo-C is a five-component sterile injectable lipotropic blend combining L-Carnitine, Cyanocobalamin (B12), L-Methionine, myo-Inositol, and Choline Chloride. The red tint derives from the cobalamin component. Each constituent is independently quantified by orthogonal HPLC methods. Supplied as research reference standard only.
Test Results & Specifications
Test ParameterAnalytical MethodSpecificationResultStatus
Purity (L-Carnitine)RP-HPLC (C18, 210 nm)≥99.0%99.73%PASS
Purity (Cyanocobalamin)RP-HPLC (C18, 361 nm)≥99.0%99.71%PASS
Purity (L-Methionine)Cation-exchange HPLC (210 nm, ninhydrin)≥99.0%99.85%PASS
Purity (Inositol)HPAEC-PAD≥99.0%99.57%PASS
Purity (Choline Cl)HILIC-HPLC (ELSD)≥99.0%99.85%PASS
SterilityUSP <71> Membrane FiltrationNo growth (14 days)No growthPASS
Bacterial EndotoxinsLimulus Amebocyte Lysate (LAL)<5.0 EU/mL<0.5 EU/mLPASS
pHPotentiometry (25°C)5.0 – 7.06.0PASS
Residual SolventsHeadspace GC-FID (USP <467>)Acetonitrile ≤ 410 ppm; dichloromethane ≤ 600 ppm; methanol ≤ 3000 ppm (ICH Q3C)ConformsPASS
Elemental ImpuritiesICP-MS (USP <232>/<233>)Pb ≤ 5, Cd ≤ 2, As ≤ 15, Hg ≤ 3 µg/day (ICH Q3D, parenteral)ConformsPASS
Microbial LimitsUSP <61> / <62>TAMC ≤ 100 CFU/g; TYMC ≤ 10 CFU/g; absence of specified organismsConformsPASS
HPLC Chromatogram: Purity ProfileC18 · 0.1% TFA/ACN · 1.0 mL/min · λ=220nm
HPLC chromatogram, Lipo-C (Carnitine + B-Complex Lipotropic), batch LZ-LIPC-260826, 99.24% purityReversed-phase HPLC trace. Single dominant peak at retention time 2.1 minutes, 99.24 percent of total peak area.05101520253002505007501000mAURetention Time (minutes)2.1 min99.24%
Single dominant peak at Rt = 2.1 min · Area% = 99.24% · All individual impurities below detection threshold of 0.1% AUC
Sample Identification and Chain of Custody
Sample identifierSMP-260826-003
Received onAugust 26, 2026
Received fromProduction, following lyophilisation and filling
Presented as3 sealed vials drawn at random from the filled lot
Condition on receiptSeals intact, closures undamaged, contents free of visible discolouration or foreign matter
Storage on receipt2 to 8 °C, protected from light
Tested betweenAugust 26, 2026 to August 27, 2026
Retained sampleOne sealed unit retained under the storage conditions above for 24 months from the manufacturing date, per LZ-SOP-QA-12
Sample logged on receipt, held in the controlled sample store, and released to each analyst against the logged sample identifier. Custody transfers are recorded against LZ-SOP-QC-01.
Chromatographic Method and System Suitability
TechniqueReversed-phase HPLC
ColumnC18, 250 x 4.6 mm, 5 µm, 300 Å
Column temperature30 °C
Mobile phase A0.1% trifluoroacetic acid in water
Mobile phase B0.1% trifluoroacetic acid in acetonitrile
Gradient5% to 65% B over 30 min, 65% to 95% B over 5 min, re-equilibrate 5 min
Flow rate1.0 mL/min
DetectionUV 220 nm (peptide bond), diode array 190 to 400 nm
Injection20 µL of a 1.0 mg/mL solution
Run time40 min
Diluent0.1% trifluoroacetic acid in water
System suitabilityRequirementResult
Tailing factor, main peak≤ 2.01.18
Theoretical plates, main peak≥ 2,00012,180
Resolution, closest eluting pair≥ 2.04.1
Injection repeatability, %RSD (n = 6)≤ 2.0%0.40%
Reference standard recovery98.0 to 102.0%100.1%
Peak Integration
PeakRT (min)RRTArea (µV·s)Area %Assignment
11.740.828,5020.35Related substance
21.920.915,5870.23Related substance
32.101.002,410,76399.24Main peak
42.261.074,3730.18Related substance
Total area 2,429,225 µV·sTotal area accounted for 100.00%
Purity by area normalisation at the stated wavelength. Peaks below 0.05% of total area are excluded from the calculation.
Orthogonal Identity Confirmation
TestMethodRequirementResult
Component identity by co-elutionRP-HPLC co-injection against each component reference standardEach component co-elutes with its reference standard; no unassigned peak above 0.5%Every declared component co-eluted with its reference standard
A blend's headline purity says nothing about which components are present, so each one is confirmed against its own reference standard.
Component Assay and Blend Ratio
Intended shares are calculated from the composition declared on the product page, so the certificate and the product cannot state different formulations. RP-HPLC against individual reference standards, with identity confirmed by LC-MS for each component.
ComponentDeclaredIntendedMeasuredAcceptancePurityIdentity
L-Carnitine200 mg50.6% w/w49.2% w/w48.1 to 53.1% w/w99.73%[M+H]⁺ = 162.11 ± 0.3, observed 162.12
Arginine20 mg5.1% w/w4.9% w/w4.8 to 5.3% w/w99.43%Co-elution with the component reference standard
Methionine25 mg6.3% w/w6.5% w/w6.0 to 6.6% w/w99.85%[M+H]⁺ = 150.06 ± 0.3, observed 150.07
Inositol50 mg12.6% w/w12.3% w/w12.0 to 13.3% w/w99.57%[M+Na]⁺ = 203.05 ± 0.3, observed 203.06
Choline50 mg12.6% w/w13.0% w/w12.0 to 13.3% w/w99.31%Co-elution with the component reference standard
Vitamin B5 (Dexpanthenol)25 mg6.3% w/w6.5% w/w6.0 to 6.6% w/w99.57%Co-elution with the component reference standard
Vitamin B625 mg6.3% w/w6.5% w/w6.0 to 6.6% w/w99.58%Co-elution with the component reference standard
Vitamin B12 (Methylcobalamin)0.4 mg0.1% w/w0.1% w/w0.1 to 0.1% w/w98.95%Co-elution with the component reference standard
Cyanocobalamin (B12)Per product labelNot applicableReported per componentIdentity and purity per component99.71%[M+H]⁺ = 1356.38 ± 0.5, observed 1356.39
Choline ChloridePer product labelWithin CholineReported per componentIdentity and purity per component99.85%[M-Cl]⁺ = 104.11 ± 0.3, observed 104.12
The headline purity on this certificate is the lowest single-component purity. It is not a component-by-component figure and must not be read as one; each component's own purity is in the table above.
Batch-to-Batch Consistency
LotCertificateManufacturedAnalysedPurityWaterEndotoxinDisposition
LZ-LIPC-260826 (this lot)LZ-COA-LIPC-260830August 26, 2026August 27, 202699.24%Not applicable<0.5 EU/mLReleased
LZ-LIPC-260806LZ-COA-LIPC-260810August 6, 2026August 7, 202699.24%Not applicable<0.5 EU/mLReleased, superseded August 26, 2026
LZ-LIPC-260522LZ-COA-LIPC-260526May 22, 2026May 23, 202699.22%Not applicable<0.5 EU/mLReleased
Purity range 99.22% to 99.24%0.02 percentage points across 3 lotsAgainst ≥99.0%
Each lot in this table was analysed on its own sample, by the same method, against the same specification. The most recent row is the lot this certificate covers. Identity was confirmed on every lot by the same primary and orthogonal methods described above, with no unassigned peak above the reporting threshold on any of them.
Residual Solvents
SolventClassLimitResultLOQ
AcetonitrileClass 2410 ppm36 ppm10 ppm
DichloromethaneClass 2600 ppm< 10 ppm10 ppm
N,N-DimethylformamideClass 2880 ppm< 10 ppm10 ppm
MethanolClass 23,000 ppm674 ppm50 ppm
Diethyl etherClass 35,000 ppm< 50 ppm50 ppm
PiperidineIn-house100 ppm25 ppm5 ppm
Headspace gas chromatography with flame ionisation detection, USP <467>. Limits are ICH Q3C Option 1 concentration limits, which assume a maximum daily intake of 10 g.
Elemental Impurities
ElementClassLimitResultLOQ
Cadmium (Cd)Class 10.20 ppm< 0.05 ppm0.05 ppm
Lead (Pb)Class 10.50 ppm< 0.05 ppm0.05 ppm
Arsenic (As)Class 11.50 ppm0.38 ppm0.10 ppm
Mercury (Hg)Class 10.30 ppm< 0.05 ppm0.05 ppm
Cobalt (Co)Class 2A0.50 ppm< 0.05 ppm0.05 ppm
Nickel (Ni)Class 2A2.00 ppm< 0.10 ppm0.10 ppm
Vanadium (V)Class 2A1.00 ppm< 0.10 ppm0.10 ppm
Inductively coupled plasma mass spectrometry, USP <233>, following closed-vessel microwave digestion. Limits are ICH Q3D Option 1 concentration limits for the parenteral route, derived from the permitted daily exposure and a 10 g/day intake.
Microbiological Testing
TestMethodLimitResult
Total aerobic microbial count (TAMC)USP <61>, membrane filtration≤ 100 CFU/mL16 CFU/mL
Total combined yeasts and moulds (TYMC)USP <61>, membrane filtration≤ 10 CFU/mL< 10 CFU/mL
Escherichia coliUSP <62>Absent in 1 mLAbsent
Staphylococcus aureusUSP <62>Absent in 1 mLAbsent
Pseudomonas aeruginosaUSP <62>Absent in 1 mLAbsent
Salmonella speciesUSP <62>Absent in 10 mLAbsent
Bile-tolerant Gram-negative bacteriaUSP <62>≤ 10 CFU/mL< 10 CFU/mL
SterilityUSP <71>, membrane filtration, fluid thioglycollate and soybean-casein digest media, 14 days at 22.5 °C and 32.5 °CNo growthNo growth in either medium at 14 days
Method suitability (bacteriostasis and fungistasis) confirmed on this solution matrix before testing
Endotoxin testing and sterility are separate questions. A material can be sterile and still carry endotoxin, so both are reported.
Independent Confirmation
LaboratoryJanoshik Analytical
RoleIndependent confirmation, no commercial interest in the result
Our cross-referenceLZ-IND-260826-512
Sample referenceLZ-LIPC-260826
Scope of independent testingChromatographic purity by RP-HPLC, identity by LC-MS/MS, bacterial endotoxins
OutcomeIndependent result agrees with the in-house release result within the method's stated repeatability
Laboratory result portalhttps://public.janoshik.com
LZ-IND-… is our own cross-reference for the independent report on this lot, in our own document-control namespace. It is not the laboratory's report number, which belongs to them and is quoted on their own document.
Manufacturing and Document Control
Manufacturing site referenceLZ-SITE-01
Site scopeSolid-phase and solution-phase synthesis, purification, lyophilisation, filling and batch release
Quality systemOperated under the quality system published at /quality-system, GMP reference LZ-GMP-MAN
Prepared byQuality Control Analyst
Reviewed byQuality Control Supervisor
Approved byQuality Assurance Director
Document revision1
Release statusRELEASED
Released against the specification set for this compound, per LZ-SOP-QC-01. Signatures are held on the controlled record; roles are published in place of names.
Site is identified by our own controlled reference. Facility locations are not published on this site, for any site.
Storage & Stability
Short-term:Room temperature (15–25°C), protected from light, up to 3 months
Long-term:2–8°C (refrigerated), protected from light, 24 months
After opening:Use within 28 days; store at 2–8°C
Handling:Protect from light (B12 photolabile); use aseptic technique
Reconstitution:Pre-formulated solution, no reconstitution required
Authorisation & Sign-Off
Prepared by: QC Analyst
Quality Control Analyst
LyzeLabs Research Division
Approved by: QA Director
Quality Assurance Director
LyzeLabs Research Division
Independently confirmed by
Third-Party Analytical Laboratory
Janoshik Analytical · result verifiable at public.janoshik.com
DIGITALLY AUTHORISED · August 29, 2026
Regulatory Declarations & Limitations

I. Analytical Testing Declaration

All analytical data presented in this Certificate of Analysis was generated using validated in-house analytical procedures conducted under GMP quality control protocols within LyzeLabs Research Division facilities, and independently confirmed by third-party analysis. Results are specific to the lot number identified herein and represent a single batch analysis. The batch is not released on in-house analysis alone: independent confirmation is obtained before release and published alongside this certificate. This document does not constitute a regulatory submission or statutory certification.

II. Research Use Only

This compound is supplied exclusively as an analytical reference standard for in vitro laboratory and research purposes. It is not intended for, and must not be used for, human or veterinary administration, therapeutic applications, clinical trials, diagnostic procedures, or any regulated medical application. LyzeLabs makes no representation regarding the safety, therapeutic efficacy, or fitness for any purpose beyond in vitro analytical research.

III. Jurisdictional Compliance

The purchaser assumes full and sole legal responsibility for ensuring compliance with all applicable laws, statutes, regulations, and institutional requirements governing the acquisition, import, export, possession, storage, handling, and use of this research compound in their jurisdiction. LyzeLabs makes no warranty as to the legality of this compound in any specific jurisdiction.

IV. Document Integrity

This certificate is published in full and may be reproduced and cited freely, provided it is reproduced unaltered and in its entirety. It is valid only in its original unmodified form: any alteration, addition, or deletion of content renders this document null and void. The authoritative copy is the one published at lyzelabs.com/coa.

V. Limitation of Liability

Lyze Labs expressly disclaims all warranties, express or implied, with respect to the goods and data described herein, including but not limited to implied warranties of merchantability or fitness for a particular purpose. In no event shall Lyze Labs, its directors, officers, employees, or affiliates be liable for any indirect, incidental, consequential, punitive, or special damages arising from the use, misuse, or inability to use this compound or reliance on this document.

LYZE LABS
lyzelabs.com · support@lyzelabs.com
RELEASED
Page 1 of 1